Instrument
Development Service Centre(IDSC)
This is an
ongoing project of the division
at the department of Physics,
Cotton College Guwahati. Under
the scheme new instrument /experimental
set up are developed as well
as instrument/experimental set
up of the colleges which become
defective are repaired. Repairing
of instruments of college laboratories
are carried out on 'first come
first service' basis. Development
of instrument/experimental set
up are also taken up on a central
need of the colleges.
Some
of the institutions which have
received services from the centre
are Cotton College, Guwahati;
North Guwahati College, North
Guwahati; M. C. College, Barpeta;
B. Barooah College, Guwahati;
Handique Girls' College, Guwahati;
Jorhat Science College, Jorhat;
Birjhora Science College, Bongaigoan;
Darrang College, Tezpur; Pandu
College, Guwahati; Pub-Kamrup
College, Baihata Chariali; B.H.
College, Srimanta Sankar Academy,
Guwahati; Solid State Laboratory,
Gauhati University; IIT, Guwahati
and College of Veterinary Science,
Khanapara, Guwahati.
Instrument
designed and developed by IDSC
Transistor
characteristic experiments (N-P-N/P-N-P);
L-C-R experiment; Anderson bridge
experiment; 'R-C couple amplifier;
Multi vibrator experiment ;
Ripple factor experiment for
full and half wave rectifier;
Low cost demonstrative experiment
using LASER ; Resonance column
experiment ; Photo - Cell experiment;
AND, NOT, NOR gate kit ; Junction
diode kit for forward and reversed
biased analysis ; Thermistor
kits etc.; Simplified GM counting
system for studying nuclear
disintegration ; Resistivity
measurement of thin metal at
different temperature; Study
the property of liquid using
laser and ripple tank ; Modification
of Melde's experiment with electronic
switch and frequency generator.
New
instrument designed and developed
 |
Micro
to mill volt converter |
 |
OPAM
checker |
 |
Temperature
controller relay drive |
 |
IC
regulated power supply etc |
New experimental
kits developed by IDSC
 |
Verification
of De-Morgan's theorem |
 |
Verification
of Norton's and Thevenin's
theory |
 |
Study
of OPAMP by measuring input
offset voltage, input offset
current and input bias current. |
 |
Study
of open loop gain of an
OPAMP |
 |
Study
of gain of an OPAMP in inverting
and non-inverting condition
(closed loop gain ) |
 |
Measurement
of Stefan constant using
thermocouple and micro to
milli volt converter. |
 |
Determination
of the value of self-induction
using L-R circuit |
Repairing
of Instrument
UPS,
C.R.O, Voltage stabilizer, VTVM,
Signal Generator, Microscope
etc., of a number of institutions
and research laboratories.
|